Case Studies & News
Fit and forget: installations still working years later
Examples of how we have replaced obsolete and non-standard equipment, re-engineered industrial applications and supported plants over the long term.
Many of these projects are not recent. Some of the installations are now 18 years old or more and still working, which is the real benefit of Beck actuators: fit and forget.
Keep the Good, Replace the Weak Link
Unreliable hydraulic actuators on sound boiler feed regulating valves replaced with Beck drives on purpose-built mounting kits. The valves are unchanged, standby valves are back in service, and there have been no known failures since.
Read the case study ›
Power Station Actuator Replacement
Obsolete hydraulic and electric actuators replaced on fan vanes, dampers and valves. One ID fan vane damper actuator, installed in 2013, made over 100 million starts in its first eight years.
Read the case study ›
Glass Furnace Actuators
Beck actuators supplied, installed, commissioned and supported on gas skids, forehearths and dampers. The gas skid drives date from 2008, and a level probe actuator has been in service for over 20 years.
Read the case study ›
Bespoke Rotary Airlock for a Steel Works
A non-standard rotary airlock with a failing rotor and leaking shaft seals, replaced with a purpose-built unit that fitted the existing chutes, with improved shaft sealing for easier maintenance.
Read the case study ›
AirSweep for a Soil Bagging Hopper
Soil bridging, worst in cold wet weather, had the loader operator hammering and rodding the hopper above a moving conveyor. Noisy vibrators had not helped. IPT designed a four-nozzle AirSweep system that keeps it flowing.
Read the case study ›
Fluid Coupling Scoop Actuator for a Plasterboard Mill
The scoop actuator on a mill fluid coupling kept failing from heavy vibration. A Beck 11-159 on a purpose-designed plinth was installed in one morning and has run without problems since.
Read the case study ›
Boiler Fan Damper Actuators at an Oil Refinery
FD fan vane and ID fan damper drives brought up to current regulations with Beck 11-209 actuators in about 2011. Both have run ever since.
Read the case study ›
Biomass Plant Damper Actuator Recommissioning
Beck actuators on FD, overfire and underfire air dampers inspected and recommissioned after damper maintenance at UK biomass plants. Every actuator was still in good condition.
Read the case study ›
Hot Air Butterfly Valves for a Steel Plant
Hard-to-maintain, non-standard hot air dampers replaced with easily stripped AMMTech valves, designed and supplied with IPT on short lead times. Nine valves, running successfully for two years.
Read the case study ›See also our overview of Beck actuator installations by sector.